Keller Series 21Y Piezoresistive Pressure Transmitters For Industrial Applications Pressure Ranges 2...1000 bar Output 4...20 mA / 0…10 V / 0,5...4,5 V (not ratiometric) Linearity (best fitted straight line) ± 0,25 %FS Storage-/Operating Temperature -40…100 °C
Keller Series 21 C Piezoresistive Pressure Transmitter For Industrial Applications, Ratiometric Output Pressure Ranges 2...100 bar Output 0,5...4,5 V ratiometric Accuracy max. ±0,25 %FS Total Error Band (0…50 °C) max. ±1,0 %FS
Keller Series 21 G Piezoresistive Pressure Transmitter For Industrial Applications Pressure Ranges Min: 0...5 bar Max: 0... 200 bar Output 4...20 mA / 0,5...4,5 V ratiometrisch Linearity (BSFL) typ. 0,25 %FS Error Band (0…50 °C) typ. 1,0 %FS
Kelle Series 21 PY "Pisello" Piezoresistive Miniature Pressure Transmitters Supply 8…28 V Pressure Ranges from 10 bar FS to 600 bar FS (abs.) Output 3-wire: 0,5...4,5 V (not ratiometric) Linearity (best fitted straight line) Standard: max. ±0,5 %FS Premium: max. ±0,25 %FS
Keller Series 22 DT
Piezoresistive Transmitters For Automotive- and Industrial Applications Pressure Range 14 bar (abs.) Supply 5 V ± 0,25 V Output 0,5 V...4,5 V ratiometric Accuracy ± 4 %FS (-40…0 °C) ± 2 %FS (0…90 °C) ± 4 %FS (90…125 °C) Protection IP67
Keller Series 22 M/S Piezoresistive Transmitters for Automotive and Industrial Applications Pressure Ranges 5...250 bar (abs./rel.) Supply 5 V ± 0,25 V Output 0,5 V...4,5 V rationmetric Accuracy (comp. range) ± 1 % FS (10...50°C) ± 2 % FS (0...80°C) ± 4 % FS (-40...125°C) Homologation: E4-110R-000036 and E4-10R-020927 Protection: IP67
Keller Series 23 / 25 Piezoresistive Transmitters Absolute-, Gauge- and Differential Pressure Pressure Ranges 0,2...1000 bar (abs./rel.) Output 0...10 V | 0...20 mA | 4...20 mA Linearity typ. ± 0,2 %FS, max. ± 0,5 %FS Stability, Range > 2 bar Stability, Range < 2 bar: typ. 0,1 %FS, max. 0,2 %FS typ. 1 mbar, max. 2 mbar
Keller Series 23 (S)Y / 25 Y
Piezoresistive Pressure Transmitters Pressure Ranges: -1...1000 bar Output 4...20 mA | 0…5 V | 0…10 V | 0,5...4,5 V (not ratiometric) Linearity: (2…1000 bar) ± 0,25 %FS Storage-/Operating Temperature: -40…100 °CError Band 0,5 %FS (0…50 °C)
Kelle Series 33 X / 35 X
Highly Precise Pressure Transmitters Mathematically Compensated / ProgrammablePressure Ranges 0,8...1000 bar (abs./rel.) Output Signal: RS485 (digital) | 4...20 mA (2-wire) | 0...10 V (3-wire) | 0…2,5 V / 0…5 V (3-wire) | 0,1…2,5 V (3-wire) Accuracy, Error Band (10…40 °C): typ. 0,05 %FS (digital) typ. 0,1 %FS (2-wire) typ. 0,1 %FS (3-wire)
Optional: Precision (only for Series 33 X and for ranges > 10 bar) typ. 0,01 %FS (digital) Long Term Stability typ. Gauges: 1 mbar or 0,05 %FS Absolute: 0,5 mbar or 0,025 %FS (10…40°C) Resolution: 0,002 %FS
Keller Series PD-39 X
(Ex) Differential Pressure Transmitters Based on two Absolute Sensors
Output 4...20 mA (2 Wire) 0...10 V (3 Wire) Error Band typ. < 0,05 %FS Long Term Stability typ. 0,1%
Keller Series 41 X / 41 X Capacitive Transmitter From 1 mbar Full Range / Resolution 1 µbar Pressure Ranges: 30 mbar / 100 mbar / 300 mbar (rel./diff.) Output: 4...20 mA | 0...10 V Error Band (10…50°C): 0,1 %FS typ. / 0,2 %FS max. Operating Temperature: -20...80 °C Comp. Temp. Range: 10...50 °C
Pressure Transmitters for Hazardous Applications
Keller Series 4 LC…9 LC Piezoresistive OEM Pressure Transmitters -40…150 °C, with Embedded Signal Conditioning
Pressure Ranges 1...1000 bar (abs./rel.) Accuracy max. 0,25 %FS
Keller Series 23 (S) Ei, 25 (S) Ei and 26 Ei
Pressure Transmitters For Hazardous Applications Pressure Ranges, 23 Ei / 25 Ei / 26 Ei: -1...1000 bar (abs./rel.) Pressure Ranges, 23 S Ei: 2... 200 bar (abs./rel.) Pressure Ranges, 25 S Ei: 2... 20 bar (abs./rel.) Output: 4...20 mA, 2 wire | 0...10 V, 3 wire Linearity: ± 0,5 %FS Stability, Range > 2 bar: typ. 0,1 %FS Stability, Range < 2 bar: typ. 2 mbar
Keller Series 23 Ed / 25 Ed, 33 X Ed / 35 X Ed Piezoresistive Transmitters with Pressure Proof Housing For Hazardous Applications Pressure Ranges: 0,1...300 bar (depending on type; see data sheet) Output: 4...20 mA | 0...10 V | RS485 Accuracy / Error Band: see data sheet Stability, Range > 1 bar: typ. 0,1 %FS Stability, Range < 1 bar: typ. 1 mbar Comp. Temp. Range: -10...80 °C
Keller Series 33 X Ei, 35 X Ei, 36 XW Ei, PD-33 X Ei Highly Precise Pressure Transmitters For Hazardous Applications Pressure Ranges: 1...1000 bar (see data sheet) Output: RS 485 | 4...20 mA, 2 wire | 0...10 V, 3 wire Accuracy / Precision: (see data sheet) Stability, Range > 1 bar: 1 mbar Stability, Range < 1 bar: 0,1 %FS
Series PD-39 X Ei Differential Pressure Transmitters Based on two Absolute Sensors Standard Pressure Ranges: see data sheet Output: 4...20 mA (2 Wire) | 0...10 V (3 Wire) Error Band: typ. < 0,05 %FS Long Term Stability typ.: 0,1%
Keller Series 41 X / 41 X Ei Capacitive Transmitter From 1 mbar Full Range / Resolution 1 µbar Pressure Ranges: 30 mbar / 100 mbar / 300 mbar (rel./diff.) Output: 4...20 mA | 0...10 V Error Band (10…50°C): 0,1 %FS typ. / 0,2 %FS max. Operating Temperature: -20...80 °C Comp. Temp. Range: 10...50 °C
Keller Series 46 X / 46 X Ei Capacitive Transmitters For Water Level Measurements Pressure Ranges: 30 mbar / 100 mbar / 300 mbar (rel.) Output: 4...20 mA | 0...10 V Error Band 10…50 °C: 0,1 %FS typ. / 0,2 %FS max.
Pressure Transmitters for Biotechnology / Food Industries
Keller Series 25 F Piezoresistive Transmitters For Food Industries Pressure Ranges 0,2...400 bar (abs./rel.) Output 0...10 V | 0...20 mA | 4...20 mA Linearity typ. ± 0,2 %FS Stability typ. ± 0,1 %FS
Keller Series 35 X HT(T) Piezoresistive Transmitters For Applications in Bio-Reactors or Autoclaves Pressure Ranges -1...30 bar (abs./rel.) Output RS485 | 4...20 mA (2-Wire) | 0...10 V (3-Wire) Accuracy (20…120 °C): 0,15 %FS (RS485) 0,2 %FS (2-/3-Wire) Resolution 0,002 %FS Stability, Range > 2 bar: 2 mbar Stability, Range < 2 bar: 0,2 %FS Storage- / Operating Temp. Range: -20…150 °C (electronics max. 120 °C)
Keller Series 35 X HTC High Temperature Pressure Transmitters For Biotechnology / Food Industries Pressure Ranges: 0...1000 bar (abs./rel.) Output: RS485 | 4...20 mA | 0...10 V Precision: 0,5 %FS Linearity (best straight line): 0,05 %FS Storage-/Operating Temperature Range Media: 0…300 °C Electronics: 0…120 °C
Piezoresistive Force Transmitter
Keller Series FA-23 Piezoresistive Force Transmitters Series FA-23 Force Ranges: 0…15 kN Output 0,5...4,5 V | 4...20 mA Linearity typ. 0,5% Total Accuracy 0...50 °C ± 1 %FS
Intelligent Transmitter with Digital Indication
Keller LEO3 Digital Manometer Bus-capable / Programmable 4...20 mA Output. Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.1 Ranges: 3, 30, 300, 700 & 1000 bar
Smart Pressure Transmitters
Rosemount 3051 Rosemount 3051 Pressure Transmitters With its time-tested reliability and over 4 million installations, the Rosemount 3051 is more than field proven – it is the Industry Standard.
The 3051 delivers unparalleled reliability, performance and safety to increase your plant profitability. Better measurement means a stronger bottom line. The comprehensive offering enhances your pressure, level and flow applications from simple measurement to stringent SIL2 safety compliance.
Measurement Type: Differential, Gage, Absolute, Level, Flow Output: 4-20 mA HART, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5 Vdc HART Low Power Reference Accuracy: ± 0.065% of span with 0.04% Optional Total Performance: ± 0.15% of span Long Term Stability: ± 0.125% of URL for 5 years Rangedown: 100:1
Rosemount 2051 The Rosemount 2051 family of pressure transmitters empowers you to measure pressure with confidence.
The 2051 provides a reliable differential, gage, and absolute pressure measurement with a variety of output protocols, materials and process connections. Meet your pressure, level, and flow application needs with its flexible Coplanar™ platform so that you can lower project and ongoing maintenance costs.
Measurement Types: Differential, Gauge, Absolute, Level and Flow Output: 4-20mA HART®, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power Reference Accuracy: ± 0.075% of span Long Term Stability: 0.1% of URL for 2 years Rangedown: 100:1
Rosemount 2088 Rosemount 2088 Gage & Absolute Pressure Transmitters The Rosemount 2088 is a highly reliable and accurate transmitter in a lightweight, compact package. The 2088 can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 4000 psi (275.8 bar). It can also be used to measure negative pressure ranges. The 2088 measurement capabilities enable reliable use in almost any application.
Measurement Type: Gage, Absolute Outputs HART, Low Power HART Reference Accuracy: ± 0.10% of Span Stability: ± 0.10% of URL for 12 months
Rosemount 3051S Rosemount 3051S Scalable Level Transmitter The Rosemount 3051S Scalable Level Transmitter will maximize your level measurement success by providing superior performance and best-in-class reliability. Combined with the comprehensive Rosemount 1199 Seal Systems offering, the 3051S can meet all your level application needs. Measurement Type: Differential and gage level measurement Product Configurations: 3051S_L with flush and extended diaphragm seals 1199 Remote Seal optional Output: 4-20mA HART™, FOUNDATION™ fieldbus, WirelessHART™ Reference Accuracy: 0.065% of span Rangedown: 100:1