Keller CaliLP / CaliMP / CaliHP Pressure Calibrators Low-, Medium- and High Pressure Pressure Ranges Low Pressure -1...10 bar Pressure Ranges Medium Pressure -1...25 bar Pressure Ranges High Pressure 0...700 bar Total Accuracy typ. ± 0,05 %FS / max. ± 0,1 %FS
Calog Pressure II Calibrator Pressure II Calibrator The - Pressure II is the ideal calibrator for testing, measuring and calibration of all pressure based systems. In addition it contains functions to install and maintain all powered and non-powered milliamp loops.
Features: Measure, source or simulate 0 to 24 mA Measure 0 to 32 Vdc Continuity test function Increment, step, auto step or ramp with built-in 24V power supply for mA loops Displays values in mA and % or % and mA Keller series PA-33x Digital Pressure sensors used Pressure readings in many different units: bar, mbar, kPa, MPa, psi, m H2O, in H2O, ft H2O, mm Hg, cm Hg, in Hg, kg/cm2, atm. Logged data is downloaded via the onboard USB port Contains a simple pressure conversion menu Trend logging with programmable timebase of all measured values Carry case, protective rubber boot, Li-ion battery, charger, test leads and SD card supplied as standard 1 year guarantee against faulty material or workmanship (batteries not included)
GE Druck DPI 620 DPI 620 Advanced Modular Calibration and HART® Communication System. The DPI 620 Series an ultra-compact electrical, temperature and frequency calibrator and HART communicator, which provides simultaneous measurement and source capabilities with a fully featured HART digital interface. It integrates with pressure modules and pressure generation stations to form uniquely capable pressure test and calibration systems.
The Intrinsically Safe version of the DPI 620 Series is now available allowing configuration and multi-function calibration in hazardous areas. The ATEX and IECEx certification allows the instrument to be employed globally in Zone 0 areas. The certification also applies to the instrument’s battery pack, permitting hot swapping within hazardous locations. The approval now further extends the range of potential applications of the powerful communicator/calibrator, especially in the oil and gas and process sectors. As with all instruments in the DPI 620 family, the IS version with IP65.
GE Druck PV 621, 622 & 623 Pressure Stations There are three pressure generation stations, also available in ATEX approved versions for stand- alone use in hazardous areas:
PV 621 - pneumatic pressure generator for pressures 95% vacuum to 20 bar (300 psi) PV 622 - pneumatic pressure generator for pressures 95% vacuum to 100 bar (1500 psi) PV 623 - hydraulic pressure generator for pressures up to 1000 bar (15000 psi).
Each pressure station is designed for stand-alone operation as a pressure generator and can replace conventional hand pumps and gas bottles to provide greater efficiency and ease of use. They can be used on the workbench or combined with a reference instrument, such as the DPI 104 they can be used as comparators and pressure calibrators.
Combining any of the pressure stations with a PM 620 pressure module and the DPI 620 calibrator creates a uniquely capable, self-contained pressure calibrator.
GE Druck DPI 610/615 A highly accurate and easy to use calibrator is only part of the solution for improving overall data quality and working efficiency. The DPI 610 and DPI 615, with data storage and RS232 interface, reduce calibration times and eliminate data recording errors. The DPI 615 also provides error analysis for field reporting of calibration errors and pass/fail status. In addition, procedures downloaded from a PC automatically configure the DPI 615 to pre-defined calibration and test routines. 52 Ranges from 2.5 mbar to 700 bar Accuracy from 0.025% F.S. Integral combined pressure/vacuum pump 4 to 20 mA loop test facility RS 232 interface and fully documenting version Up to 11 sensors per instrument
GE Druck DPI 610/615 LP Series DPI 610/615 LP Series - Portable Low Pressure Calibrators The DPI 610/615 low pressure calibrator versions enable the end user to calibrate draft range instrumentation in the field.
This feature minimizes the effects of moving the unit under test and any offsets that may occur. The test data can then be stored for uploading to your computer at a more convenient time. Features: Generates and measures very low pressure Ranges ±1 to ±50 inH2O Accuracy 0.05% FS Dedicated tasks and dual readout Automatic system vent and display zero RS 232 interface and documenting versions
Pressure Calibration Pumps
Keller Low pressure base Calibrator-Device with Digital Manometers Low Pressure Base Pressure Ranges -850 mbar...10 bar For further information please contact your nearest KELLER sales person.
Keller HTP1 High Pressure-Handpump
Pressure Ranges up to 700 bar
This pump allows easy pressure generation up to 700 bar. Suitable pressure media are hydraulic oil or water. The oil chamber volume of 100 cm3 will fill large dead volumes.
The pump with its fine pressure adjuster and vent valve enables precise pressure settings, which makes it to an ideal test equipment for manometers and pressure transmitters.
(the HTP1 pump is delivered without the digital manometer)
Keller Hand pump K/P Hand pump K/P
Pressure Ranges -0,85…25 bar
Negative pressures/vacuums and pressures of up to 25 bar (max. 40 bar) can be generated with this pneumatic hand-pump.
Thanks to the fine adjustment valve (which is integrated in the pump) and the relief valve, a calibration pressure can be set accurately and quickly. This handpump is therefore highly suitable for testing manometers and pressure transmitters.
Keller Pump P12 High Pressure-Pump
Pressure Ranges bis 700 bar
This pump allows easy pressure generation up to 700 bar. The pressure media is hydraulic oil. The oil chamber volume of 148 cm3 will fill even big dead volumes.
The pump with its fine pressure adjuster and vent valve allows precise pressure settings, which makes it to an ideal test equipment for manometers and pressure transmitters.
(the pump is delivered without the digital manometer)
Pressure Digital Test Gauges
Keller LEO1 / LEO1 Ei Digital Manometer Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.1 Ranges: 3, 30, 300, 700 & 1000 bar
Keller LEO2 / LEO2 Ei Digital Manometer Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.1 Ranges: 3, 30, 300, 700 bar
Keller LEO3 Digital Manometer Bus-capable / Programmable 4...20 mA Output. Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.1 Ranges: 3, 30, 300, 700 & 1000 bar
Keller ECO1 / ECO1 Ei Digital Manometer Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.5 Ranges: -1...30, 0...300 bar
Keller LEX1/ LEX1 Ei (Highly Precise) Digital Manometer Pressure port G1/4" Compensated temperature range 0...50°C Accuracy at room temperature [%FS] 0.05 (Optional precision 0.025 & 0.01) Ranges: -1...2, -1...20, 0...200, 400, 1000 bar
Keller Mano Gauge / Mano Record / Mano Cali Mano Gauge (Basic Version) Display of: Pressure, Pressure Unit, Temperature, Elapsed Time (Alternative: Max.- and Min. Value). Also available in Ex ia-version.
Mano Record (Mano Gauge plus Data Recording) Based on the Mano Gauge, the Mano Record records and stores the measured values. Memory for 16'000 or optionally 32'000 readings. Also available in Ex ia-version.
Mano Cali (Calibrator Version plus Data Recording) In the basic mode, the Mano Cali displays: Pressure, Pressure Unit, Max.- and Min. Values. Units are selected via the front key (bar, PSI, kPa, MPa,). Mano Cali also incorporates the functions TARA (sets a new temporary zero reference), LEAK (measures a pressure change over a programmable time) and RES (reduces the standard resolution by factor 10).
Pressure Ranges Mano Gauge/Record 30 mbar...1000 bar Pressure Ranges Mano Cali (-1) 2...700 bar
Total Accuracy Mano Gauge/Record typ. ± 0,1 %FS
Total Accuracy Mano Cali typ. ± 0,05 %FS
Keller DV-2 Digital Pressure Gauge For High Volume Applications Compensated temperature range 0...40°C Accuracy: Version Standard: 0,5 %FS Version Silver: 0,2 %FS Version Gold: 0,1 %FS Ranges: -1...3, -1...30, 0...200 & 700 bar
Keller DV-2 Cool Digital Pressure Gauge For Refrigerant Examination Operating temperature range 0...50°C Accuracy: 0,1 %FS Ranges (abs): -1...40, -1...80 Refrigerant: The following refrigerant are stored in the instruments: R22, R12, R507, R404a, R134a.